Bug 8867 - Unable to update TP 37 > 50 over Wireless
: Unable to update TP 37 > 50 over Wireless
Status: CLOSED INVALID
Product: SB Transporter
Classification: Unclassified
Component: Setup
: 50
: PC Windows XP
: -- normal (vote)
: 7.1
Assigned To: Felix Mueller
:
Depends on:
Blocks:
  Show dependency treegraph
 
Reported: 2008-07-25 10:33 UTC by James Richardson
Modified: 2008-08-04 14:00 UTC (History)
1 user (show)

See Also:
Category: ---


Attachments
Failing Log (243.17 KB, application/octet-stream)
2008-07-25 10:33 UTC, James Richardson
Details
Working Log (77.37 KB, application/octet-stream)
2008-07-25 10:33 UTC, James Richardson
Details

Note You need to log in before you can comment on or make changes to this bug.
Description James Richardson 2008-07-25 10:33:07 UTC
Created attachment 3681 [details]
Failing Log

I was unable to update the Transporters firmware from r37 (7.0.1) to r50 (7.1) when the transporter was attached to the server via Wireless.

Over wired it works fine.  Downgrading from 50 > 37 works fine wired or wireless.

Working and Failing logs attached.
Comment 1 James Richardson 2008-07-25 10:33:27 UTC
Created attachment 3682 [details]
Working Log
Comment 2 James Richardson 2008-07-25 11:03:31 UTC
To correct this issue, I had to power cycle the device by removing the AC plug to get 50 to install properly.
Comment 3 James Richardson 2008-07-25 11:53:49 UTC
Well, it looks like this may be my system only.  Chris was unable to reproduce it, and after a few power cycles on my system I am not unable to reproduce it.