Bug 4728 - Alarm Volumes inc-/decreases in steps of 2 or 3
: Alarm Volumes inc-/decreases in steps of 2 or 3
Status: CLOSED FIXED
Product: Logitech Media Server
Classification: Unclassified
Component: Player UI
: 6.5.1
: Macintosh Other
: P2 normal (vote)
: ---
Assigned To: Chris Owens
:
Depends on:
Blocks:
  Show dependency treegraph
 
Reported: 2007-02-03 06:25 UTC by Gerd Boerrigter
Modified: 2008-12-15 11:58 UTC (History)
1 user (show)

See Also:
Category: ---


Attachments

Note You need to log in before you can comment on or make changes to this bug.
Description Gerd Boerrigter 2007-02-03 06:25:26 UTC
The volume setting in the alarm goes in steps of 2 or 3. Example: MUTED, 2, 5, 7, 10, 12, 15, etc.
It should increase and decrease in steps of 1.

I believe the alarm is internally still on a 0 - 40 scale, instead of 0-100. The steps of 2 or 3 might actually be a step of 2.5. The solution of bug 4095 might just make that invisible.
Comment 1 KDF 2007-02-04 15:23:45 UTC
fixed in trunk at change 11337
and in 6.5.2 at change 11338
Comment 2 Gerd Boerrigter 2007-02-11 10:25:35 UTC
Great. Works for me, too.
Thanks for the fast response.
Comment 3 James Richardson 2008-12-15 11:58:14 UTC
This bug has been fixed in the latest release of SqueezeCenter!

Please download the new version from http://www.slimdevices.com/su_downloads.html if you haven't already.  

If you are still experiencing this problem, feel free to reopen the bug with your new comments and we'll have another look.