Bug 10183 - IR remote switch causing SBC to get lost
: IR remote switch causing SBC to get lost
Status: CLOSED INVALID
Product: SB Controller
Classification: Unclassified
Component: SqueezeNetwork
: unspecified
: PC Windows Vista
: -- major (vote)
: 7.3
Assigned To: Ben Klaas
:
Depends on:
Blocks:
  Show dependency treegraph
 
Reported: 2008-11-30 22:06 UTC by James Richardson
Modified: 2008-12-11 09:33 UTC (History)
3 users (show)

See Also:
Category: ---


Attachments

Note You need to log in before you can comment on or make changes to this bug.
Description James Richardson 2008-11-30 22:06:24 UTC
Using the SBC to control the SB3, if I use the IR remote to switch the SB3 from SC 7.3 to Production.SN, the controller does not switch.

Controller has 7.3r3437

Using the SB3 UI to switch from SC>SN will result in the SBC giving a bounce

Power Cycle did not resolve the issue, I still get the bounce.

Log Attached
Comment 1 James Richardson 2008-12-01 13:38:47 UTC
Ben: I am able to repro this, what logs on the SBC do you want me to set to debug?
Comment 2 James Richardson 2008-12-01 13:45:31 UTC
This only happens with an SB3.  Boom / Transporter / SB2 moved from 7.3 SC -> SN and back are OK.

Tested 3 different SB3's all with firmware r119
Comment 3 James Richardson 2008-12-01 14:47:34 UTC
The comments on this bug are all screwy..closing and opening a new bug that only talks about 'IR remote switch causing SBC to get lost'